Hi, I have a problem with Ph diffusion. I used 1um thick thermal oxide as masking material for Ph diffusion. The predeposition was run at 900C for one hour and the drive was run at 1100C for half hour. However, I found out that oxide peeled off at the edge of the pattern during the process and caused lateral Ph diffusion underneath the oxide pattern. Does anyone know the cause of the peeling problem and the proper way to do the Ph diffusion? Thanks, Jin -- Jin Zheng Michigan Technological University 121 EERC Building, 1400 Townsend Dr. Houghton, MI 49931