Does your mask make a good contact with the samples? I had this problem when my samples had edge bead. It sounds like also underexposed. Patrick Poissant ___________________________________________________ M.A.Sc. Student Dept. of Electrical Engineering Université de Sherbrooke Sherbrooke (Québec) J1K 2R1 CANADA patrick.poissant@usherbrooke.ca Sherbrooke Microelectronics Research Group www.gel.usherb.ca/gms Anyone who has never made a mistake has never tried anything new - Albert Einstein ----- Original Message ----- From: "suscarl"To: Sent: Wednesday, September 08, 2004 11:15 AM Subject: [mems-talk] unwanted tapering of SU-8 structures > Need advice from SU-8 experts: > I have 30um width by 55um height SU-8 2035 lines. Somehow, after 35s exposure time and post-bake of 95oC for 20min, the resulting structures are tapered with bottom 60um width and top 40um width. Can anyone offer possible solutions to troubleshoot the problem? > > Thanks!! > _______________________________________________ > MEMS-talk@memsnet.org mailing list: to unsubscribe or change your list > options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk > Hosted by the MEMS Exchange, providers of MEMS processing services. > Visit us at http://www.memsnet.org/ > >