Jiang, The glass transition temperature (Tg) of unexposed SU-8 is ~55C. Your bond is currently running at 75C. The further you get away from the Tg, the less viscous the material will become. One thing to try would be to reduce your bonding temperature to increase the viscosity of the SU-8. For the second suggestion, it really becomes important as to how you are applying your bonding force. If you are using an actual dedicated bonding system (such as an EVG520 or EVG501), the force is very controllable, so you may want to experiment with different bonding forces. If you are pressing by hand, then try placing objects of known weight and uniform weight distribution on top of the stack, and slowly ramp the "weight" up. Best Regards, Chad Brubaker -----Original Message----- From: Jiang Ziling Subject: Su-8 bonding clogging problem I tried to make channel by bonding two Glass wafers, one with a 50um exposed Su-8 layer with channel on it, another with a 50um unexposed Su-8 layer. According to some research, at 75 degree centigrade the unexposed Su-8 can reform shape and bond with the exposed layer when certain pressure is applied. But I tested and found that the 100um wide channels on the exposed su-8 surface are always clogged by the soft Su-8 flowing from the unexposed layer during pressing-bonding. However, if I don't press, there will be no bonding. Does anyone have experience in solving this clogging problem?