Hi Jiang, your clogging problem is concerned by the low Glass transmission temperature of unexposed SU8 (Tg=55°C). You should try it with both wafers exposed. You can use a flood exposure. Then you can raise the bonding temperature up to 100°C without having any clogging. best regards Ulrike Schömbs -----Ursprüngliche Nachricht----- Von: Jiang Ziling [mailto:spmtfmpcs@gmail.com] hi all, I tried to make channel by bonding two Glass wafers, one with a 50um exposed Su-8 layer with channel on it, another with a 50um unexposed Su-8 layer. According to some research, at 75 degree centigrade the unexposed Su-8 can reform shape and bond with the exposed layer when certain pressure is applied. But I tested and found that the 100um wide channels on the exposed su-8 surface are always clogged by the soft Su-8 flowing from the unexposed layer during pressing-bonding. However, if I don't press, there will be no bonding. Does anyone have experience in solving this clogging problem?