Michael L
2005-06-28
Hi Mohammed,

The main approaches involve surface modification via adhesion promoters
(e.g. HMDS) or oxygen plasma treatment. You could try both: O2 treatment
followed by HMDS - remember to dry your wafer in a convection oven at 150
deg C prior to using HMDS.

Good luck.

Michael


>
>Hi all
>I need to decrease the contact angle while reflowing microlenses.Can
>somebody suggest a practical way of increasing the hydrophillicity of
>Si-substrate wrt PR(AZ9260cp).