Greetings, We use SU materials, however did not experience swelling. I must add that our materials are baked at the highest temp given in the data sheets. Also we are able to remove the PR using An spinner rather than dipping etc Typical removal time is 15 seconds for 2 microns. Kind Regards Walther www.elume.com -----Original Message----- From: Silvan Schmid [mailto:silvan.schmid@micro.mavt.ethz.ch] Sent: Monday, November 07, 2005 2:24 AM To: mems-talk@memsnet.org Subject: [mems-talk] Protection Layer for SU-8 Structures Dear all, I have SU-8 structures which I need to cover with a photoresist layer in order to protect them during the dicing process. The solvent to remove the protection layer should not alter the SU-8 (e.g. SU-8 will swell in acetone). Do you have any experience, which photoresist/developer pair is best suited for this task? Thanks! Regards, Silvan