Happy New Year! I think it might be helpful to keep you guys posted about my testing. Today, I used a larger container for SU8 developer ( I used to use a 4in glass petri-dish) and refresh developer after each use. The fabrication process is the same as before. For the first sample, 1 min of development is barely enough. I can see the trace amount of residual remaining in the channel. So I continue the development in 2nd fresh batch of developer for 15 sec. The channel is clean now, but the bright spot appeared at the acute angel of the Y shape channel. This is at least better than the picture I posted in the original message where the channel is surrounded by bright spots. For the second one, I do the development in the first batch of developer for 1.5 min, then need to remove some trace residue in a second batch for 15 sec. No bright spots found in this case. For the third one, I switched back to petri-dish. 90 sec development followed by 45 sec development in two petri-dishes cannot fully remove the trace amount of PR in the channel. I did a 30 sec rinse in a large beaker with fresh developer and the result was better. And no bright edge in this case. For now, it seems that using more developer might help. However, I compared the difference between beaker and petri-dish about 2 months ago, and at that time, there was no difference -- see bright edges in both cases. Anyway, thanks for reading this message and any further input would be greatly appreciated. Best, Liu Yu