----- Original Message ----- From: "GARCIA BLANCO Sonia"To: Sent: Friday, January 27, 2006 10:12 AM Subject: [mems-talk] Residues after development using SU8 2075 > Dear All, > > I am having quite a lot of difficulty developping the recipe for > 150microns > thick layers of SU8 2075 on fused silica substrated sputtered with gold > (4inch wafers). My main problems are: > > (a) Sticking of the wafer to the mask. > (b) Some non-developped stuff stack to my patterns and I cannot get rid of > that only if I reduce the dose and then, I begin havng some initiation of > adhesion problems. > Hi Sonia, I have the similar problem of your first one before. I think that is because your softbake didn't get rid of solvent in SU-8 completely. Try to softbake at 95 degree C for a longer time. That should be able to solve the problem. At least, it worked for me. I am not quite sure about your second problem. But I guess it might be due to the reflection from your gold layer. That might expose some areas you don't want to. Good Luck Richard