Dear James, Yes, this has been discussed before actually... :-) However, I'm quite intrigued to see that you are working with the SU-8 3000 series! From where have you purchased this? I have heard for a long time that MicroChem would put out a new series of SU-8, but I have not been able to find out any more info about it...could you fill me in? And in what way does the 3000 series differ from the 2000 series?? Have you tried any of the other series and have you so experienced any differences? About your question: low adhesion with SU-8/metal is a problem in general. We have done a study on it and you can find the work in Microelectronic Engineering 78-79 (2005) 152-157. There are two things you could try: (i) increase the exposure dosage, that generally improves the adhesion or (ii) use an adhesion layer such as Ti or Cr, about 50 Å. Good luck! Sincerely, Maria Maria Nordström, M.Sc. PhD Student, Bioprobe Group MIC - Department of Micro and Nanotechnology Technical University of Denmark DTU bldg. 345 east DK-2800 Kgs. Lyngby Denmark Tel: +45-4525-5759 Fax: +45-4588-7762 Email: man@mic.dtu.dk Web: www.mic.dtu.dk/Research/BioProbe.aspx -----Original Message----- From: James Zhu [mailto:james.zhu@epigem.co.uk] Sent: 8. marts 2006 10:11 To: General MEMS discussion Subject: [mems-talk] Problems due to poor SU8 adhesion to metal surface Dear all, I am new in this field and also this community.I am probably asking some silly questions. Thanks for any help in advancen anyway. I used SU8 3000 Series spin coated on nickel or silver surface. It was followed by pre-bake for 11 mins at 95 C, exposure 7sec, PEB 1 mins @65C + 4 min @95C and develop. Everything is ok until electroplating in copper (strong acid) or gold bath (strong basic) simply because Su8 layer detached from the metal surface. Can anybody please give me some advice to overcome or just let me know ther it is a unsolved problem. Many thanks! James