Hi all, In Tsau's paper, in pre-bonding cleaning for Au-Au thermocompression bonding, to ensure removal of organics, the substrates were exposed to UV-ozone for 90 min immediately prior to wafer alignment. But we don't have that equipment. So, my question is: Would dipping into Piranha be helpful? (Since it can remove organics.) Or should O2 plasma cleaning be better? (Since it can remove organics too.) Thanks! Hu Xiaodong Hu_xiaodong@163.com Hebei Semiconductor Research Institute