Hello, For the micro fabricated bio chip/ micro fluidic devices Class 1000/100 required, although it is dependent on the fabrication protocol and materials as well as dimension. Usually polymer based micro fluidic devices demand class 1000/100 for the fabrication. For the cleaning you can use Decon 90 and followed by IPA in the ultrasonic bath. It will remove micro/nano monomer. Regards, Mamun Rashid PhD Candidate Centre for Nano & Microsystems University of Teesside TS1 3BA. U.K www.mamun.info -----Original Message----- From: mems-talk-bounces@memsnet.org [mailto:mems-talk-bounces@memsnet.org] On Behalf Of hammouche khales Sent: 06 July 2007 02:59 To: mems-talk@memsnet.org Subject: [mems-talk] polymer fabrication Hellos all, I have some questions if there is one ho need to help me! - i need to have some informations for polymer fabrciation (especially using PDMS ), and if there is contaminations problems with CMOS process? - what the clean room class if we need to fabricate bio-chip (or microfluidic devices)?