Pramod, What you are seeing is likely local arching within the plasma. Local arching can create feedback that causes the plasma to "flicker" as you say. This is usually caused by organic contamination that is outgassing or even sputtering during the etch cycle. Higher power levels will also exacerbate the problem as will moisture in the chamber. Tuning the current or plasma density is key to a robust process. I am curious if you would see "sparkles in the plasma at lower power levels, say 125 - 175W. As you know the [F+] radical is very reactive and can be prone to external reactions. What I have found to be of help in the past is a thorough polymeric residue clean of, not just the chamber, but the electrodes as well, followed by a bake out under HiVac to drive off moisture. Good Luck! Mike Michael W. Stan Sr. Technical Sales Representative MicroChem Corporation 1254 Chestnut St. Newton, MA 02464 (617) 965-5511 ext. 237 (508) 335-2911 (mobile) mstan@microchem.com -----Original Message----- From: mems-talk-bounces@memsnet.org [mailto:mems-talk-bounces@memsnet.org] On Behalf Of PRAMOD GUPTA Sent: Monday, November 12, 2007 6:39 PM To: General MEMS discussion Subject: [mems-talk] Reasons for Plasma Flickering in Oxford Plasmalab 80Plus RIE system Hi Does any one know what could be the reasons for Plasma Flickering in Oxford Plasmalab 80 Plus RIE system?. I am trying to etch polymers with SF6/O2/CHF3 gas chemistry at 30mTorr, 200W. The recipe was working perfect earlier. Pure O2 plasma, even at 30mTorr, does not flicker at all. It starts flickering when you mix O2 with SF6 and/or CHF3. What could be the reasons?