Hello, everyone, I met another problem on SU-8 process. Wrinkles are found on the sidewall surface of SU-8 structure, like 5 X 1 X 0.4 mm cuboid and 50 X 0.1 X 0.4 mm narrow cuboid, after exposure and development. The soft-bake temperature is 100 celsius degree/ 2hours, and the post exposure bake temperature is 100 celsius degree/ 1hour. The exposure doses are from 600-1200 mJ/cm2. Also delamination was found after development. I thought this is due to internal stress, and I tried to lower the post-exposure-bake temp. down to 80 celsius degree/ 2 hour. But wrinkles are still there, and the amount is not reduced obviously. Is anyone have some idea about this problem? Please give me some advice. Thanks a lot ! wrinkles are shown in this picture: http://farm3.static.flickr.com/2147/2547007289_bbd840d815.jpg?v=0 -- Best Regards, 郑瑞麟 Ruilin Zheng Address: Pen-Tung Sah MEMS Research Center, Xiamen University, Xiamen,361005, P.R.China