Hey Jay, It seems to be a classic case of poor adhesion. What's the substrate and what procedure did you carry out prior to the deposition of the metal layers? Also, the 1st layer seems a bit thin for good adhesion. Trent Jie Zou wrote: > Hey everyone, > > Using a Photoresist S1813 - LOR3A bilayer, I evaporated about 3nm Cr (as > adhesion) 120nm gold and 130nm Cr (from bottom to top). Then I lifted it > off. So far so good. I need to do a e-beam lithography after that. Thus I > spinned PMMA A4 and baked it @ 180 C (30mins in oven). After I lift-off or > just washed away the PMMA, I found parts of the metal layer detached and it > coiled itself. I ran a test that without the PMMA, I directly baked the > sample with the metal layer on the hot-plate, and the detachment happened > again. I also tried a sample with only 120nm gold or only Cr layer (and the > 3nm Cr adhesion layer) baking under the same condition. It is fine. > > I think this detachment and coiling is due to the stress difference between > the Cr and Au, since I don't have any problem with only gold or only Cr. > When I heated my sample, the two metals extended and release its stress in > different ways. > > Sometimes the first evaporation also failed. I think it was also due to the > high temperature in the evaporation chamber. > > Anyone had the same experience and any suggestion? Is there some annealing > process I could try?