Dear Andrea, You should completely cure the SU8 after patterning & if I remember well (you can check SU8 files) that means treatment (ramp up to 200 & after cool down) at 200 C for 10 min (depending on layer thickness). If you had a vacuum oven will be better. The cracks appear because of vacuum and because the su8 isn't completely cured (95 is too low no matter how long you keep it). If you want to do lift off after metal deposition better use omnicoat before su8 deposition. Best regards, Dr. Mihaela Carp Der all, I'm trying to evaporate chromiun onto uncrosslinked SU-8, i have read the other message present in the forum written in the past about "wrinkles on SU-8" e i had follow the suggestions, but at the end of story i have still problems. This problems are deep crack onto Uncrosslinked SU-8. This Crack/Wrinkles appears immediately after the deposition of Chrome. I use SU-8 2002 to have a thikness of about 2,5 um and i have been performed the thermal treatment of the SU-8 with an hot plate. The fabrication process is the following: 1) Wafer cleaning 2) spin Su-8 2002 1000rpm 9(ramp) 30'' (about 2.5 um of thickness) 3) Soft Bake ramped until 95°C (from 20°C to 95°C with a ramp of 2°C/min and hold at 95°C for 1hour and then a cool down ramp until 20°C in about 1 hours ) (The long soft bake is performed in order to evaporate the solvent present in the SU-8 ) 4) Exposure 10'' with the conventional paramenters given by Microchem 5) Long Post Exposure Bake (2' @ 95°C and hold at 60°C for 20 hours and then a cool down ramp until 20°C ) (2' @95°C for the crosslik of the exposed SU-8 insteand the Long Post Exposure Bake is performed in order to evaporate the remaining solvent present in the uncrosslink SU-8 and also in order to avoid outgassing problems for the next metal deposition) 6) Evaporation of 30nm of Chrome by Thermal Evaporation (filament) with a chamber's vaccum of 3,6 e -7 millibar with deporate of 3A/s For the deposition of chromium no metal deposition technologies that expose the uncrosslinked SU-8 to photons is used ,i.e. sputtering or electron beam metal deposition, in order to prevent the crosslink of uncured SU-8. And so i use filament evaporators that utilize Joule effect to vaporize the metal. Chromium at a pressure of 3,6 e -7 millibar sublimates at approximately 977 °C and the peak of the blackbody radiation is theoretically calculated to be in the infrared range (about 4 um) with no generation of photons which crosslink the uncured SU-8. Before the deposition of chrome all appear to be ok, i also tried to develop the SU-8 and the uncrosslink SU-8 is perfectly dissolved with is developer. Now my question is.... "where did I go wrong??"...By chance is it something in the deposition? Or in the thermal treatment of the SU-8? Or both of these things? Any suggestion are welcome. Thanks in advance Andrea Lucibello