Hey TJ, i cover my wafer using TDTS (Tridecafluoro-1,1,2,2-tetrahydrooctyl-trichlorosilane) from www.abcr.de (english website) for one hour in a simple desiccator with a standard vacuum rotary vane pump attached. The desiccator is sealed and the pump is switched of after 30min and then a wait another 30min before venting. That works very well. Some of my wafers were covered with pdms and peeled off several hundred times without any problem. I use a home-made Plasma chamber with 0,1mbar oxygen and a tesla coil with 500kV for 20s. After 30min, the PDMS devices are very stable and can be filled with fluid. I never found any Silane attached to the device. Maybe you want to try TDTS oder do you silane evaporation a little longer. Or maybe your Plasma-procedure was too long. When i apply the plasma for 30s or more, the pdms is covered with a thin film of glas (depending on the applied energy). That won't stick as well. Good luck!! Best regards, Lukas @ÜÄ schrieb: > Thank you! > > I think the silane treatment time may be a problem. > > I did 15 minutes of silane, as I've read off from a paper. > > I'll try doing at least an hour and see how it goes. > > Again, thank you so much! > > > Best, > > TJ