Paul, 100um of resist suggests no need for high resolution, sub micron. Simple plasma with an inert gas will abrade the surface and give more surface area and good adhesion. If chemical adhesion to the resist is a must, the general problem is insufficient dehydration and then allowing the wafers to see moisture before applying adhesion promoter. If you do a careful matrix doing one vacuum purge followed by a hot nitrogen gas reduces rough edges by about 50% indicating a better adhesion. A second vacuum hot Nitrogen purge reduces rough edges even more. A third vacuum/hot Nitrogen purge removes all observable rough edges. And a final vacuum dehydration ensures complete adhesion. Let me know if you need any help. Bill Moffat -----Original Message----- From: mems-talk-bounces@memsnet.org [mailto:mems-talk-bounces@memsnet.org] On Behalf Of Paul Nguyen Sent: Tuesday, November 24, 2009 7:15 AM To: MEMS-talk@memsnet.org Subject: [mems-talk] How to improve adhesion of resist to a metal surface Dear ALL, Beside best surface cleanliness pre-coating, what other techniques would improve adhesion of photoresist (very thick up to 100um) to a metal surface, in particular a NiCo surface? I would appreciate input from MEMS experts. Happy Thanksgiving to ALL! Best regards, Paul Nguyen