Mufei, The surface and interface between pads might have fracture after ultrasonic bonding. The excessively deformed metals might change contact resistance between pads due to excessive bond force. Thank you and best regards, JTD -----Original Message----- From: mems-talk@memsnet.org On Behalf Of mufei gong Sent: Monday, March 22, 2010 8:38 AM To: mems-talk@memsnet.org Subject: [mems-talk] wire bonder ruined my device Dear all, When I use an west bond 7400A Aluminum ultrasonic wirebonder , before I did the wirebonding, the resistance between the two metal pads was >10 Mohm, but after I did the wire bonding, the resistance dropped to a few hundred ohm to a few kohm. the other ends of the two metal pads are separated by a 150 nm trench of GaAs. This happened to 3 of my devices, and now I only have one left... does anyone know what might be the cause of this?