Hi, everybody: Does anyone knows or has experience to measure or calculate the power consumption of ZnO piezoelectric transducers? Now, I'm trying to measure it and compare with commercial electromagnetic dynamic acoustic transducers. But, strangely, piezo acoustic transducers give more power consumption as follows. But normally, considering the advantage of piezoelectric acoustic transducers, shouldn't the power consumption of piezoelectric transducer bellow than the one that of dynamic transducers? Is there any misunderstanding in my way to measuring the power consumption ?Dc resistance = infinity AC current = 0.36 mA AC voltage = 7.1Vrms Therefore, R= 7.1/0.00036 = 1.97E4 ohm Therefore, P= square(7.1V)/(1.97E4 ohm) = 2.5 mWatt Dc resistance = 28 ohm AC current = 4.4 mA AC voltage = 0.035Vrms Therefore, R= 8.03 ohm Therefore, P = square(0.035V)/(8.03 ohm) = 0.15 mWatt