Hi Shay, Thanks a lot for the suggestions. Make sure to pump the system to e-7 before introducing the ar-------- after baking for like 2hrs and use a almost a new rough pump the system goes to 4e-7, I never reach e-7. Also, try to sputter cr onto a shutter befor coating your sample-------- this is a good point, I will try it. Thanks again, and have a wonderful weekend, Yassine, Ait El Aoud On Wed, Jan 26, 2011 at 3:02 PM, Shaywrote: > Yassine, > > Make sure to pump the system to e-7 before introducing the ar. Also, try to > sputter cr onto a shutter befor coating your sample. > > Shay