Dear Khaled Ramadan, Thank you very much for your suggestion. Yes, I often take the spin coating after pour PR out and put the sample on a hot bake immediately. In fact, the soft baking temperature is set about 65 (C), lasting 1 hr. And then I change the temperature of soft baking to 95 (C) for another hour. I have discovered that the bubbles appear after several minutes of first soft baking stage. They will disappear in the second stage gradually. But the thickness of the edges of sample is larger than that of inner area. That mean, it will make a small gap between mask and sample surface when exposure, it may cause to some error on the pattern. For PR removal, I will try with piranha clean. I do hope it can be removed without any damage of structure. Thanks, Best regards, Le Hong PhD student Department of Mechanical Engineering National Central University, Taiwan ________________________________ From: Khaled Mohamed RamadanTo: Le Hong Hanh ; General MEMS discussion Sent: Wednesday, June 8, 2011 9:12 PM Subject: Re: [mems-talk] Su-8 cannot be removed! Dear Le Hong, It is very true that with a non circular wafer, you cant get a uniform thickness especially with large thicknesses. for the bubbles, try to do the spinning immediately after you put the SU8 on the wafer.with very large thicknesses, I recommend you bake at smaller temperature with longer times. This will decreases the issue of bubbles appearing while soft baking and will reduce the internal stress on the film. If you bake only at 65, "Longer Times" would mean triple to 4 times the soft baking at 95. For removal, once you cross-link the su-8 with exposure, it is very hard to remove it with any thing. For me honestly, nothing removes Cross-linked SU8 but piranha clean. This is because cross linked SU-8 is meant to be remaining as a structure. Thanks Regards, Khaled Ramadan