The fault may be with the bonding unit. I have several customers doing Silicon Wafer to Silicon wafer bonding using about 10 minutes plasma no heat. Others doing a flexible polymer to glass with a 20 second plasma no heat, contact me for further information. Bill Moffat -----Original Message----- From: mems-talk-bounces+bmoffat=yieldengineering.com@memsnet.org [mailto:mems- talk-bounces+bmoffat=yieldengineering.com@memsnet.org] On Behalf Of ??? Sent: Tuesday, August 16, 2011 1:19 AM To: mems-talk@memsnet.org Subject: [mems-talk] Glass-glass bonding problem Dear everyone: Does anyone who has the available process to do the glass-glass bonding? I have tried several times with the glass-glass bonding, and I have used RCA1# solution and O2 plasma activation for assistant, but finally I can't realize the bonding. The process temperature is about 200~300 ℃ ,and the bonding pressure is about 2000N, 6' Pyrex7740 glass wafer, 500um thickness. The bonding machine is EVG520. Thanks to any help. Regards. Evan J