The only solution is to perform on-chip serial measurement. In that way measurement is non sensitive to parasitic capacitors (like in SC electronic circuits) At 17:16 01/12/98 +0800, you wrote: >hi there! i encountering the same problem. how do detect such small >capacitance of 1fF? > >---------- >> From: Chieh-Hsiao Wang>> To: MEMS@ISI.EDU >> Subject: capacitive sensor measurement >> Date: Thursday, November 19, 1998 3:31 AM >> >> Dear Colleague: >> >> Capacitor in MEMS is usually very small (~ fF). >> How can I measure the capacitance of this kind of capacitor at the >> presence of large parasitic capacitor and resistor? >> >> --- >> Chieh-Hsiao Wang >> chhwang@iastate.edu >> Department of ECpE >> Iowa State University >> > >