Hi,Aslam I experimented with TMAH etching last year. The same problem appeared at that time. As the silicon wafer was etched, more pyramidal hillocks were found on the surface. They not only affect the roughness of the etched surface, but also prevent the following etching. The etching seems to be negligible when hillocks become more and more. The available solutions are to increase the etching temperature, add some strong oxidizers and lower the solution concentration of TMAH water. In addition, please note that first, the solution has to be stirred magnetically during the etching; secondly, TMAH solution tends to volatile. At last I think too long etching time is not suitable for TMAH solution. Maybe you alternate another kind of etchants. Good luck Zhu Xiaorui China,People's Republic zhuxiaorui zhuxiaorui@public.cta.cq.cn