Dear all: I want to make some metallic pattern(Ti/Au-40nm) by E-beam lithography and sputtering. My experiment requires some flat electrodes about 100nm(width). E-beam evaporating with carbon crucible is not suitable to this purpose. (You can see the AFM image at http://phya.snu.ac.kr/~lsjun/111.jpg) Is it safe to deposit metals by sputtering in the lifeoff of PMMA? Thanks in advance. Sungjun Lee ------------------------------------------------------------- Mr. Sungjun Lee Center for Science in Nanometer Scale, Inter-University Semiconductor Research Center, Seoul National University, Seoul, 151-742, South Korea Mobile:+82-16-2264658 Fax:+82-2-8748926 Mail:poyntor@yahoo.com -------------------------------------------------------------