Hi, you need to use graphite electrode to avoid the pits. we use both (steel and graphite electrodes) in U of Michigan, and the results are consistent. jun ----- Original Message ----- From: "Brett Swope"To: Sent: Wednesday, July 31, 2002 9:47 AM Subject: [mems-talk] Anodic Bonding - Glass Pits > I am attempting to set up an anodic bonding tool that will be able to > uniformly bond 3" wafers. At this point I am able to bond Corning 7070 > Borosilicate glass to Si wafers but after the wafers have cooled there appears > to be minor defects in the glass surface in the form of 'pits'. Each pit is > less than 50 um in diameter and hundreds are spread randomly throughout the > glass. My setup is as follows: > > Temp: 400 C > Voltage: 500-1200 V > Time: 1-5 mins > Electrodes: 304 Stainless Steel (lapped and polished on glass contact > surface) > > Has anyone ever heard of this? I have looked through some literature but > haven't found anything like this. > > Any help is appreciated! > Brett Swope > _______________________________________________ > MEMS-talk@memsnet.org mailing list: to unsubscribe or change your list > options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk > Hosted by the MEMS Exchange, providers of MEMS processing services. > Visit us at http://www.memsnet.org/