Hi Kasey, Below 400C you might try Cr/Cu/Co/Au, see J/ Appl. Phys. 70(3) 1374 (01 Aug 1991). While I'm no expert, I've also heard that TiN might work. Good Luck, Mike >>> kui-xiang_ma@agilent.com 10/7/2003 5:07:14 AM >>> Hi all, I look forward to hearing your comments and suggestion how to get rid of Cr from top surface of my sample. My ceramic substrate is deposited with Cr and Pt, respectively. Due to either process or post annealing, Cr migrates to surface and gives more than 10% concentration. The surface Cr brings me with serious wetting problem, so that I need to reduce Cr concentration on the surface as much as possible. Appreciate it very much if any one could recommend me what good solutions are, together with process conditions / parameters. Thanks so much for your kind help! Best regards, Kasey Ma _______________________________________________ MEMS-talk@memsnet.org mailing list: to unsubscribe or change your list options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk Hosted by the MEMS Exchange, providers of MEMS processing services. Visit us at http://www.memsnet.org/