Hello, I will try to deposit low temperature oxide at 400C on sputtered Ni film. Does anyone know whether Ni film can survive the 400C temperature? I have experiences on depositing LTO on Pt and Cr and both metal were fine, but I found that Ti film used to agglomerate at about 300C. Thanks, Li ************************************************** Li Shi Mechanical Engineering Department University of California Berkeley, CA 94720 E-mail: lishi@newton.berkeley.edu Phone: (510)643-3007 Fax: (510)642-6163