We have a BOC Edwards Auto 500 Sputtering system. The normal glow plasma color was light green, but it is pink. I still can deposit Au films with lower deposition rate but not Si, instead I got transparent films. I suspect the chamber has leakage and the Si could be oxidized. Does anybody has the same experience? Please advice. Bing