Hi Michael, I am using glass microchannel with 150 x 150 micrometer cross section. On Fri, Mar 15, 2013 at 12:11 AM, Michael Martin < michael.martin@themicrowerks.com> wrote: > Hi Avinash, > > What material are your channels made from? If it is PDMS then you might > have had them change back to a hydrophobic state. I hear that if a plasma > activated channel is left in air for even a short time (~hours) at room > temperature, hydrophobic sections of the polymer will migrate to the > surface thus creating a larger back pressure and causing hydrophobic > material in the flow stream to precipitate out. So evidently you should > keep PDMS chips in water at all times. > > Hope this helps, > Michael > > > On Mar 13, 2013, at 4:41 PM, Avinash sahuwrote: > > > hi all, > > I have some issue related to microchannel hope you can resolve it. Please > > suggest me the way to remove the blockage and cleaning procedure in > > microchannel. One of the my microchannel was blocked by bromothymolblue > dye > > and Phenolphthalein dye solution and in other channel I had good flows > like > > slug, stratified etc at starting but now not even slug flow is not > comming. > > The slug flow comes at lower flow like 0.01 - 0.1 ml/min. I am using Y > > junction mirochip 150x150 micrometer. I tried using Isopropyl alcohol, > > acetone, 35% HCL,35%H2O2, H2SO4, sonication at 35 Hz and 135 Hz for both > > cleaning and blockage purpose, nothing is working. Please help me with > this > > I will be thankful for you. > > > > -- > > Avinash Sahu > > MS Research Scholar > > Chemical Engineering > > IIT Madras (T.N.) 600036 > > 9003387409(M) > > Profile Page > > http://www.che.iitm.ac.in/~spush/avinash.html > > For details on the International Conference Mathematics in Chemical > > Kinetics and Engineering- please visit > > http://www.mackie2013.iitm.ac.in/ > > _______________________________________________ > > Hosted by the MEMS and Nanotechnology Exchange, the country's leading > > provider of MEMS and Nanotechnology design and fabrication services. > > Visit us at http://www.mems-exchange.org > > > > Want to advertise to this community? See http://www.memsnet.org > > > > To unsubscribe: > > http://mail.mems-exchange.org/mailman/listinfo/mems-talk > _______________________________________________ > Hosted by the MEMS and Nanotechnology Exchange, the country's leading > provider of MEMS and Nanotechnology design and fabrication services. > Visit us at http://www.mems-exchange.org > > Want to advertise to this community? See http://www.memsnet.org > > To unsubscribe: > http://mail.mems-exchange.org/mailman/listinfo/mems-talk > -- Avinash Sahu MS Research Scholar Chemical Engineering IIT Madras (T.N.) 600036 9003387409(M) Profile Page http://www.che.iitm.ac.in/~spush/avinash.html For details on the International Conference Mathematics in Chemical Kinetics and Engineering- please visit http://www.mackie2013.iitm.ac.in/ _______________________________________________ Hosted by the MEMS and Nanotechnology Exchange, the country's leading provider of MEMS and Nanotechnology design and fabrication services. Visit us at http://www.mems-exchange.org Want to advertise to this community? See http://www.memsnet.org To unsubscribe: http://mail.mems-exchange.org/mailman/listinfo/mems-talk