Suzanne, I have experience using Polyimide as a sacrificial layer. At first I tried to use an RIE (Trion type). This did not work. It left material under the Aluminum bridge. What you want is an asher, which can produce an isotropic plasma. I use a plasma which is 70% O2, 30% CF4, by pressure (don't have MFC's on our asher, so I use the vacuum guage and needle valves to control the flow). I use 1 Torr pressure. This works quite well. The CF4 increases the etch rate greatly, and does not attack SiO2 or Si in this system (or I couldn't measure the etch rate if there was one.) If you are intersted I can send more details. Also, Aluminum is not a great material for bridges. I deposited it using an e-beam, and it had compressive stress, so it tended to buckle, or look "wavy" after release. Good Luck, Rob